| CSM2000 Multi Parameter |
|
- 12.1” TFT color LCD display, optional multi language operation menu;
- ST segment analysis: both automatic and manual function;
- 24 hours electrocardiograph play-back, with 20 kinds of arrhythmia analysis functions;
|
|
|
|
|
- 12.1” TFT color LCD display, optional multi language operation menu;
- ST segment analysis: both automatic and manual function;
- 24 hours electrocardiograph play-back, with 20 kinds of arrhythmia analysis functions;
- Trend chart analysis; real time/trend display in one screen, 12/24/96 hours optional;
- Save kinds of data while measuring blood pressure, maximum 400 sets of data;
- Can display maximum 8 waveforms in one screen,
- Available with 1 lead / 3 lead / 7 leads ECG trace display,.
- Safety protection from defibrillation and electrosurgical units; application with pacemaker available;
- Dual protection by software and hardware from over blood pressure;
- Multi-grade alarm function with alarm display;
- 7-grade volume digital control on alarm, ECG and pulse;
- Available to connect with central network to set up central monitoring system;
- Digital measuring technology on pulse oximetry;
- Optional medication concentration analysis function;
- Optional infant respiration analysis function;
- Optional pacemaker analysis function
- Optional parameters as dual channel invasive blood pressure, CO2, depth of anesthesia;
- Optional power supply used specially in ambulance.


|
ECG
|
Heart rate measuring range |
15bpm-300bpm |
|
Resolution |
1bpm |
|
Accuracy |
± 1 % ,2bpm(max) |
|
ECG magnifying width |
Monitor : 0.5Hz - 40Hz |
|
diagnostic : 0.5Hz - 75Hz |
|
Leads selection
|
Standard pressed body
Lead:AVR 、 AVL 、 AVF 、 thorax V1-V6 |
|
ST segment examination |
-0.2 ~ 2.0mV 、 automatic |
|
arrhythmia analysis |
yes |
|
electrode falling off indicating |
Sound and light display |
|
Scan speed |
12.5 、 25 、 50mm /sec |
|
Gain |
x1/2 、 x1 、 x2 、 x4 、 Auto |
|
Anti-interfere |
Resistence of high frequency interiferences , Anti high frequency interfere, anti body electric interfere, anti-defibrillation |
|
ECG leads
|
standard |
Adult universal ECG lead |
|
optional |
Kid,infant universal ECG lead |
|
Alarm |
Alarm max/min setting, automatic memory |
Non invasive blood pressure
|
Measuring method |
intelligent vibrating |
|
Parameters measured |
systolic, diastolic, mean, pulse rate |
|
Measuring mode |
manual, automatic. 5 minutes continuous measuring |
|
Measure range
|
Adult/ Pediatric
|
Systolic:25mmHg-265mmHg |
|
Diastolic:12mmHg-220mmHg |
|
Mean:18mmHg-245mmHg |
|
Infant
|
Systolic:25mmHg-135mmHg |
|
Diastolic:12mmHg-110mmHg |
|
Mean:18mmHg-120mmHg |
|
Cuff pressure range |
0mmHg-300mmHg |
|
unit |
MmHg/kPa optional |
|
Cuff |
Standard |
Adult |
|
Optional |
Infant, pediatric |
|
Cuff charge time |
< 10s |
|
Release time after measuring |
≤ 2s |
|
Alarm |
Alarm max/min setting, automatic memory |
Temperature
|
Range |
25 - 45 |
|
Resolution |
0.1 |
|
Probe |
Standard |
Body surface permanent probe |
|
Optional |
Gullet/Recta probe |
|
Alarm |
Alarm max/min setting, automatic memory |
Pulse Oximetry & Pulse Rate
|
Display |
Pulse oximetry value, pulse column chart, waveform, pulse rate |
|
Measuring range |
35% ~ 100% |
|
Resolution |
1% |
|
Accuracy
|
± 2%(90%-99%) |
|
± 4%(70%-89%) |
|
± 6%(40%-69%) |
|
Pulse oximetry measuring range |
15bpm-300bpm |
|
transducer
|
Standard |
Adult finger |
|
Optional |
Pediatric clip, Infant binding |
|
Alarm |
Alarm max/min setting, automatic memory |
Respiration
|
Method |
Thorax impedance detection |
|
Measuring range |
0-100bpm |
|
Accuracy |
± 2bpm |
|
Alarm |
Alarm max/min setting, automatic memory |
Printer
|
Printer |
Optional internal thermal recorder |
|
Printing method
|
Real time or waveform and text recording turned off by incident |
|
Power adaptor |
100-250VAC 50/60Hz |
|
Power |
≤ 80VA |
|
Weight |
6.5Kg |
|
Size |
370H X 330L X 160W(mm) |
|
Battery |
Lead Acid , Airproofed, Maintenance free |
|
Battery duration |
≥ 2hrs |
|
Trend time |
1-96hrs |
|
Security Level |
EN IEC60601-1(GB9706.1) |
Configuration
|
Standard |
All lead ECG, non-invasive blood pressure, Pulse Oximetry Saturation, Respiration, temperature, pulse, internal battery, parts for adult |
|
Parts
|
1 set ECG 5 lead transducer, 1 set Adult blood pressure cuff, 1 pulse oximetry probe, 1 temperature probe, 1 bag of ECG electrode, 1 power cable, 1 earthing conductor, 1 anti-dust cover |
|
Option |
Int ernal thermal printer, dual channel invasive blood pressure, CO2, anaesthesia depth, assembly frame |
Display
T12.1 color LCD |
|
| |
|
|